Your browser doesn't support javascript.
loading
Show: 20 | 50 | 100
Results 1 - 1 de 1
Filter
Add filters








Language
Year range
1.
Rev. venez. oncol ; 24(1): 2-18, ene.-mar. 2012. ilus, tab
Article in Spanish | LILACS | ID: lil-704410

ABSTRACT

Presentar nuestra experiencia en utilización del ganglio centinela en cáncer de mama precoz. Entre mayo 1998 y julio 1999 realizamos la identificación del ganglio centinela utilizando azul de isosulfán en 40 pacientes con carcinoma mamario, todos ganglios clínicamente negativos. El ganglio centinela fue determinado en 28 casos (70%), siendo positivo en 8 (36,4%). Desde agosto1999 - abril 2011, realizamos determinación del ganglio centinela mediante técnica combinada Linfazurín® 1% y/oazul patente 3% + 99m Tc (1 500 mCi 12 horas antes de la intervención 733/726 pacientes, todos axila clínicamente negativa. 5 falsos negativos (22,7%).Últimos 15 casos porcentaje de detección subió 73,3% falsos negativos solo 9,1%. La identificación fue posible solo con azul en 702/733 (95,67%) y solo con 99mTc en720 (98,22%) y en 728/733 (99,32%) al combinarlos. En cinco (0,68%) no fue posible localizar el ganglio centinela por ninguno de los dos métodos. Axila fue positiva en 175/733 casos (23,87%), siendo el centinela el único ganglio positivo en 84 (48%), micro-metástasis 42/175 casos (24%). 10 falsos negativos en 175 axilas positivas (5,71%). Sensibilidad del procedimiento combinado es 92,3% con especificidad 100%. Valor predictivo positivo 100% negativo 97,05%. Factores pronósticos más importantes para ganglio positivo fueron grado nuclear, invasión linfovascular. La combinación de azul con 99m Tc es idónea con alta sensibilidad y especificidad del procedimiento


Present our experience in utilization of sentinel lymph node in early breast cancer. We realized identification of sentinel lymph node utilized isosulfan blue in 40 patients with breast cancer, all of them with nodes clinical negative between May of 1998 to July1999. The sentinel lymph node was determinate in 28 cases (70%) it was positive 8 (36.4%). Until August 1999 - April 2011 realized the sentinel lymph node determination with combined technique Linfazurin 1% blue patent 3% + 99mTc(1500 mCi 12 hours before intervention. 733/726 patients with clinical negative axillaries. 5 negative false (22.7%). Last 15 cases percentile of detection was increased 73.3% negative false only 9.1%. Identification were possible only with blue 702/733 cases (95.67%) only with 99m Tc in 720 (98.22%) in 728/733 when combined both. Five (0.68%) was not possible localization of sentinel forany of two methods. The axils were positive 175/733 cases (23.87%) only positive node was the sentinel in 84 (48%), micro metastases 42/175 s (24%). 10 negative falser 175 positives axillaries (5.71%). The sensitive of combined procedure was 92.3% with specificity 100%. Predictive positive value was 100% negative 97.05%. Prognostic factors more important positive nodule were nuclear grade, and lymphatic vascular invasion. The combination of blue with 99m Tc is a procedure with high sensitive and specificity


Subject(s)
Female , Sentinel Lymph Node Biopsy/methods , Early Detection of Cancer/methods , Lymphatic Metastasis/pathology , Breast Neoplasms/complications , Breast Neoplasms/diagnosis , Breast Neoplasms/pathology , Axillary Vein/surgery , Axillary Vein/cytology , Models, Anatomic , Medical Oncology
SELECTION OF CITATIONS
SEARCH DETAIL